•24 kinds of commonly used functions to meet more application requirements; can control solenoid valves, pumps, motors, light strips, etc.
•>>Output power: can control DC or AC load within 5A ; >>Time range: 0.01 seconds to 999 minutes adjustable at any time
•>>Description of the wiring port: 1, DC: input DC power supply positive 2, DC-: input DC power supply negative 3, IN: signal input positive 4, IN-: signal input terminal 5, NO: Relay normally open interface, the relay is suspended before the suction, after the suction and short circuit with COM 6, COM: relay common interface
•7. NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed. Button trigger: (positive trigger: DC- and in- short circuit, DC and IN button Or: (negative trigger: DC and in short circuit, DC- and IN- button)
•Button Setting Instructions: - Power on display "————" means to enter standby mode; - Press K1 for the first time (it takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjusts the main mode, K3K4 adjustment function - Press K1 for the second time, the screen displays: A001: K2 and K3 adjust the first time A, K4 adjusts the decimal point (time unit)
•- Press K1 for the third time, the screen displays: B001: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit) - Pressing K1 for the fourth time, “————” means to enter standby mode - Press K4 in standby mode to permanently turn off/on the display and switch the low power mode
•Decimal Time Unit Description: - X.XX decimal point in hundred, timing range: 0.01 seconds to 9.99 seconds - XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds - XXX has no decimal point, timing range: 1 second to 999 seconds - XXX. The decimal point is in one place, the time range is from 1 minute to 999 minutes.
•Function List: P-11: Jog (give the signal relay, the signal disappears and the relay stops) P-12: Self-locking (send a signal relay to pull in, then give a signal relay to stop) P-13: Give the signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay. P-14: Give the signal, the relay will stop automatically for A seconds; trigger the retime during the delay.
•P-15: Give the signal, the relay will stop automatically for A seconds; trigger the superimposed timing during the delay. P-16: Give signal, the relay will stop automatically for A seconds; trigger reset during delay P-17: Give the signal, the relay is closed, the input signal is disconnected, the power is turned off after A seconds, and the signal is kept output again during the delay.