new | Ground temperature sensor, Temperature and humidity sensor probe, I2C interface Digital output, 14 bit resolution, for weather station, warehouse, construction site(SHT20)
Brand : Acogedor
new | Ground temperature sensor, Temperature and humidity sensor probe, I2C interface Digital output, 14 bit resolution, for weather station, warehouse, construction site(SHT20)
Brand : Acogedor
Availability : 
Out Of Stock
Click to connect with our customer support
Product Specifications
ConditionNew
AsinB08439QNRQ
CategoryIndustrial & Scientific
SubcategoryTemperature Probes & Sensors
LeafcategoryBISS Basic
MPNAcogedor3txe4gufoy-01
OriginUSA
BrandnameAcogedor
Height0.67
Length7.87
Width5.51
Weight1
Product Details
This soil temperature and humidity sensor is a digital output with a resolution of up to 14 bits.
Internal self-calibration, no calibration required. High reliability and long-term stability. The combination of temperature and humidity is convenient for dew point measurement.
The product is compact in structure and I2C output, suitable for field application and product integration. The sensor is dustproof, anti-leaching, and adopts aviation joints. It can be directly replaced during maintenance, and no need to repeat wiring.
Because the brass structure can be used in high temperature and high humidity environment, the temperature resistance is higher than that of the plastic case.
Suitable for computer room monitoring, HVAC, weather station, warehouse, construction site, concrete test block inspection, agricultural greenhouse, flower nursery, etc.
Product Description
Specification:

Item Type:Soil Sensor

Working Current:<10mA

Temperature Measuring Range:-20~100℃
Humidity Measurement Range: 0~100%RH
Working Conditions: - 40 ° C ~ 125 ° C, 0 ~ 99% RH
Storage Conditions: - 20 ° C ~ 80 ° C, 0 ~ 95% RH
Line Length:150cm / 59.06in

Weight: 128g / 4.52 oz(Approx.)

FS200-SHT2X series(Optional)Humidity accuracy %RHTemperature accuracy °CVoltage VSHT20±3±0.33.3SHT21±2±0.33.3SHT25±1.8±0.23.3


Package List:
1 x Sensor

1 x Wire Marker


Note:
Relative humidity of air is a function of temperature. Air temperature has a great influence on relative humidity. Various compounds such as acid and alkali salts have a significant impact on the physical properties of water vapour. The following items should be noted when using:
1. The temperature and humidity sensor should be installed in a place where the temperature is relatively stable and most representative of the measured ambient temperature and humidity.
2. Avoid installation in places where the temperature changes drastically.
3. Avoid installation in places where the air is flowing intensively.
4. Avoid installing dead corners where air does not flow. 
5. Avoid using it in a salt spray environment.
6. Avoid use in corrosive gas environments.

Product Description
Specification:

Item Type:Soil Sensor

Working Current:<10mA

Temperature Measuring Range:-20~100℃
Humidity Measurement Range: 0~100%RH
Working Conditions: - 40 ° C ~ 125 ° C, 0 ~ 99% RH
Storage Conditions: - 20 ° C ~ 80 ° C, 0 ~ 95% RH
Line Length:150cm / 59.06in

Weight: 128g / 4.52 oz(Approx.)

FS200-SHT2X series(Optional)Humidity accuracy %RHTemperature accuracy °CVoltage VSHT20±3±0.33.3SHT21±2±0.33.3SHT25±1.8±0.23.3


Package List:
1 x Sensor

1 x Wire Marker


Note:
Relative humidity of air is a function of temperature. Air temperature has a great influence on relative humidity. Various compounds such as acid and alkali salts have a significant impact on the physical properties of water vapour. The following items should be noted when using:
1. The temperature and humidity sensor should be installed in a place where the temperature is relatively stable and most representative of the measured ambient temperature and humidity.
2. Avoid installation in places where the temperature changes drastically.
3. Avoid installation in places where the air is flowing intensively.
4. Avoid installing dead corners where air does not flow. 
5. Avoid using it in a salt spray environment.
6. Avoid use in corrosive gas environments.