product-image
product-image
product-image
Product Image
    1
    2
    3
new | Chenbz X-WTH1 DC 6-30V Humidit and Temperature Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat Scientific Experiment Module
Brand : Chenbz
new | Chenbz X-WTH1 DC 6-30V Humidit and Temperature Controller Module Wet Control Switch Constant Sensor Dual Output Thermostat Scientific Experiment Module
Brand : Chenbz

 20,154.00
M.R.P : 33,590.00

40% OFF

Availability : 
In Stock

*Prices subject to change due to market. The price shown in the checkout is the guaranteed price.
20,154.00
M.R.P : 33,590.00

40% OFF

Availability : 
In Stock
Delivery :
Available This pincode is not serviceable! Please try with a different pincode Checking...
Quantity
7 days   Replacement
7 days Replacement
Manufacturers Warranty
Manufacturers Warranty
Top Brand
Top Brand
Free delivery
Free delivery
Secure Transaction
Secure Transaction
Blue Dart Delivered
Blue Dart Delivered
100% Guarantee Safe Checkout
  • visa
  • mastercard
  • discover
  • Maestrocard
  • paypal
  • americanexpress
  • paytm
  • upi
Note: Please be aware that products from the USA may come with an input voltage of 110V - 120V, requiring the use of an appropriate step-down transformer for compatibility. Understanding the device's wattage is essential for selecting the correct power converter.
Product Specifications
Conditionnew
AsinB08YZ4H597
CategoryIndustrial & Scientific
SubcategoryTemperature Controllers
LeafcategoryHome
MPNChenbz
OriginUSA
BrandnameChenbz
Height1
Length1
Width1
Weight1
Product Details
2. It is eas to use securit, energ saving and durable.
4. Module is eas to carr and use;
3. 100% qualit.
5. Simultaneous displa of humidit and temperature
1. The product should be broad, products with high energ efficienc, long life, low power consumption,.
Product Description
Feature:

Model: X-WTH1

Temperature range: -20 ° C ~ 60 ° C

Humidit range: 00%~100%RH

Control accurac: 0.1 °C 0.1% RH

Detection probe: integrated sensor

Output tpe: rela output

Output capacit: up to 10A

Function:

Product features are two main tpes of classification: the functions of temperature and humidit.

The function of temperature are as follows:

1. The automatic identification of work mode:

The sstem automaticall according to the start/stop temperature, identif work mode;

Start temperature > stop temperature, cooling mode'C'.

Start temperature <;; stop temperature, heating mode 'H'.

2. Cooling mode:

When the temperature≥Start temperature, rela conduction, red led on, refrigeration equipment begin to work;

When the temperature≤Stop temperature, rela disconnect, red led off, refrigeration equipment stop to work;

3. Heating mode:

When the temperature≤Start temperature, rela conduction, red led on, heating equipment begin to work;

When the temperature≥Stop temperature, rela disconnect, red led off, heating equipment stop to work;

4. Temperature correction function OFE (-10.0 ~ 10℃):

The sstem is working for a long time and ma be biased, through this function correctl, the actual temperature = measuring temperature + calibration value;

How to set the start/stop temperature:

1. In the running interface, Long Press ' TM+ ' ke more than 3 seconds, into the start temperature settings interface, can be modified b TM+ TM-ke, to be modified, waiting for 6s automatic exit and save;

2. In the running interface, Long Press ' TM-' ke more than 3 seconds, into the stop temperature settings interface, can be modified b TM+ TM-ke, to be modified after the parameters, waiting for 6s automatic exit and save;

The humidit function
We are a produ
Product Description
Feature:

Model: X-WTH1

Temperature range: -20 ° C ~ 60 ° C

Humidit range: 00%~100%RH

Control accurac: 0.1 °C 0.1% RH

Detection probe: integrated sensor

Output tpe: rela output

Output capacit: up to 10A

Function:

Product features are two main tpes of classification: the functions of temperature and humidit.

The function of temperature are as follows:

1. The automatic identification of work mode:

The sstem automaticall according to the start/stop temperature, identif work mode;

Start temperature > stop temperature, cooling mode'C'.

Start temperature <;; stop temperature, heating mode 'H'.

2. Cooling mode:

When the temperature≥Start temperature, rela conduction, red led on, refrigeration equipment begin to work;

When the temperature≤Stop temperature, rela disconnect, red led off, refrigeration equipment stop to work;

3. Heating mode:

When the temperature≤Start temperature, rela conduction, red led on, heating equipment begin to work;

When the temperature≥Stop temperature, rela disconnect, red led off, heating equipment stop to work;

4. Temperature correction function OFE (-10.0 ~ 10℃):

The sstem is working for a long time and ma be biased, through this function correctl, the actual temperature = measuring temperature + calibration value;

How to set the start/stop temperature:

1. In the running interface, Long Press ' TM+ ' ke more than 3 seconds, into the start temperature settings interface, can be modified b TM+ TM-ke, to be modified, waiting for 6s automatic exit and save;

2. In the running interface, Long Press ' TM-' ke more than 3 seconds, into the stop temperature settings interface, can be modified b TM+ TM-ke, to be modified after the parameters, waiting for 6s automatic exit and save;

The humidit function
We are a produ